As a factory-direct room thermostat manufacturer and supplier in China, we produce CE and RoHS certified smart thermostats for water-based underfloor heating and cooling systems at our own factory in Jiaxing, Zhejiang Province. With in-house PCB assembly, firmware development, ageing tests and 100% functional testing on every device, we supply OEM underfloor heating system integrators and HVAC distributors in 90+ countries with consistent, independently verified thermostats for residential, commercial and hospitality applications.
When you source room thermostats from Legom, you choose CE and RoHS certified devices that integrate directly with M30 x 1.5 thermal actuators, hydronic manifolds and the Legom base station ecosystem — supporting independent zone control, centralised multi-room management, and automatic heating/cooling changeover for heat pump systems.
We manufacture 4 room thermostat models for water underfloor heating, electric heating and radiant cooling systems. Each model targets a different control interface, feature set and installation scenario. All models are CE certified, compatible with NTC sensors and Legom thermal actuators, and support OEM and ODM customization. Apus, FC and Volcano integrate with the Legom base station for centralised multi-zone control, while the RT-X1 Ascent is a standalone 7-day programmable thermostat that switches heating loads directly.
The premium rotary-knob thermostat — the only model in the range with a tactile knob interface and the highest actuator capacity, driving up to 5 actuators at once.
| Model | Apus RT-A1 |
|---|---|
| Interface | Rotary push knob with precision ratchet + backlit LCD |
| Operating Voltage | 230VAC, 50/60Hz |
| Max Actuator Capacity | Drives up to 5 thermal actuators simultaneously |
| Operating Modes | Heating and cooling |
| Actuator Type | Supports NC and NO |
| Advanced Parameters | H1-H4 |
| Housing | 86 x 86 x 31mm; surface mount |
| Colour Options | White, black |
| Base Station Compatible | Yes |
The only thermostat with an automatic CO changeover terminal — switching between heating and cooling via a 230V signal without manual intervention.
| Model | FC FC1D |
|---|---|
| Interface | Button panel; backlit LCD display |
| Operating Voltage | 100-240VAC, 50/60Hz |
| CO Changeover | Automatic CO terminal — switches heat/cool via 230V signal |
| Operating Modes | Heating and cooling |
| Sensor | NTC; supports internal and external probes |
| Child Lock | Yes — hold Up + Down keys for 5 seconds |
| WiFi Indicator | Yes — dedicated WiFi status display |
| Advanced Parameters | H1-H4, L1, L2 (6 parameters) |
| Housing | 86 x 86 x 13mm; panel mount |
| Colour Options | White, black |
| Base Station Compatible | Yes |
The widest-voltage-range thermostat (100-240VAC) with the highest temperature accuracy of ±1°C and the richest colour choice across three variants.
| Model | Volcano RB-2305HT |
|---|---|
| Variants | RT-V1, RT-V2, RT-V3 |
| Interface | Circular display; minimalist aesthetics |
| Operating Voltage | 100-240VAC, 50/60Hz |
| Temperature Accuracy | ±1°C |
| Sensor | NTC; internal (5-35°C) and external probe (5-60°C) |
| Sensor Modes | Internal only / External only / Both |
| Housing | 86mm square; circular display |
| Colour Options | White, black, grey |
| Base Station Compatible | Yes |
The only 7-day programmable thermostat. It combines a six-segment weekly schedule with a high 16A switching capacity to drive both water and electric heating circuits in a single unit, up to 3680W.
| Model | RT-X1 Ascent |
|---|---|
| Interface | Traditional button panel; large backlit LCD |
| Operating Voltage | 230VAC, 50Hz |
| Max Load Current | 16A (up to 3680W) |
| Heating Types | Water and electric heating |
| Programming | 7-day, 5+2 or 6+1, six time segments per day |
| Sensor | NTC 10k, 1%; internal and external floor probe |
| Sensor Modes | Internal only / External only / Both (room + floor limit) |
| Temperature Accuracy | ±1°C |
| Child Lock | Yes, hold Up + Down keys for 5 seconds |
| Holiday / Energy-saving Mode | Yes |
| Temperature Protection | Configurable low and high temperature protection |
| Advanced Parameters | 10 configurable items |
| Power Consumption | Less than 1W |
| Housing | 86 x 86 x 39.5mm; 14mm slim front panel; flush mount, IP20 |
| Colour Options | White |
| Control Type | Standalone direct load switching |
All four models control water underfloor heating and support NTC sensors. Apus, FC and Volcano add cooling and base-station integration, while the RT-X1 Ascent adds 7-day programmable scheduling and electric heating support.
| Feature | Apus RT-A1 | FC FC1D | Volcano RB-2305HT | RT-X1 Ascent |
|---|---|---|---|---|
| Interface | Rotary push knob | Button panel | Buttons / circular display | Buttons + LCD |
| Voltage | 230VAC | 100-240VAC | 100-240VAC | 230VAC |
| Heating + Cooling | Yes | Yes | Yes (with heat pump) | Heating only |
| 7-Day Programmable | No | No | No | Yes |
| Electric Heating (16A) | No | No | No | Yes (3680W) |
| Automatic CO Changeover | No | Yes | No | No |
| Max Actuators | 5 | Standard | Standard | 16A direct load |
| Child Lock | No | Yes | No | Yes |
| WiFi Indicator | No | Yes | No | No |
| Temperature Accuracy | Standard | Standard | ±1°C | ±1°C |
| Colour Options | White, black | White, black | White, black, grey | White |
| Housing Depth | 31mm | 13mm (thinnest) | Standard | 14mm slim front panel |
| Advanced Parameters | 4 (H1-H4) | 6 (H1-H4, L1-L2) | Standard | 10 (richest) |
| Base Station | Yes | Yes | Yes | Standalone |
Confirm these points before ordering:
Apus uses a rotary push knob — intuitive and tactile, ideal for wet hands. FC, Volcano and RT-X1 use button panels with LCD displays for users familiar with digital menus.
For central-signal seasonal systems (e.g. heat pumps), choose FC FC1D. Its CO terminal accepts a 230V signal and switches mode automatically. Apus, Volcano and RT-X1 do not support this.
For large rooms or open spaces driven by one thermostat, choose Apus RT-A1 — it controls up to 5 thermal actuators. For standard single-actuator zones, all models apply. For central multi-room control, integrate Apus, FC or Volcano with the base station.
If heating should follow a weekly schedule, or the thermostat must control electric circuits, choose RT-X1 Ascent. It runs a 7-day (5+2) program with six segments per day and switches up to 16A (3680W).
| Production Location | Jiaxing, Zhejiang Province, China |
|---|---|
| MOQ | 1,000 units |
| Lead Time (Standard) | Confirmed at order; contact the team for current scheduling |
| Lead Time (Custom / ODM) | Project-based; agreed with the engineering team |
| Primary Export Markets | Europe (primary); 90+ countries served globally |
| Shipping | Sea / Air / Express |
| Quality Inspection | 100% PCB functional testing and ageing tests before dispatch; batch certificates available |
| Certifications | CE, RoHS |
| OEM Partners | 400+ globally |
Four models: Apus RT-A1 (rotary push knob, up to 5 actuators, 230VAC), FC FC1D (button panel, automatic CO changeover, child lock, WiFi indicator, 100-240VAC), Volcano RB-2305HT (circular display, ±1°C accuracy, three colour variants, 100-240VAC) and RT-X1 Ascent (7-day programmable, 16A switching, water and electric heating, child lock, 230VAC).
Apus has a rotary knob and drives up to 5 actuators. FC is the only model with automatic CO changeover, child lock and WiFi indicator. Volcano offers the widest voltage range, highest accuracy (±1°C) and three colours. RT-X1 is the programmable model with 7-day scheduling, 16A switching up to 3680W, child lock and holiday mode.
Yes. With a 16A switching capacity and 3680W maximum load, it controls water underfloor heating via actuators or valves, and drives electric circuits directly or via a contactor. Confirm connected load does not exceed 16A.
It runs a 7-day program in 5+2 format (one schedule for weekdays, a separate one for weekends). Each day has six time/temperature segments. You can switch to 6+1 in advanced settings; temporary manual override holds your temperature until the next segment.
Yes. All models are designed for water underfloor heating and are compatible with Legom thermal actuators (M30 x 1.5, NC and NO) as well as standard third-party actuators. NTC sensors support internal air sensing and external floor-probe sensing.
The base station is a central controller connecting all room thermostats in a multi-zone system, managing heat-source start-up from aggregated zone demand. Without it, each thermostat runs independently. You need it for centralised demand management and to coordinate changeover signals. Apus, FC and Volcano are compatible.
All are CE and RoHS certified. CE confirms compliance with European safety, EMC and low-voltage directives; RoHS confirms restricted-substance compliance. Certification documents are available on request.
Yes. They use standard relay output compatible with most 230VAC thermal actuators provided the electrical rating is within the thermostat output capacity. Both NC and NO configurations are supported.
Yes, with custom packaging, product labels and installation documentation. Firmware defaults can be adjusted, and housing colour, label printing and display language customization are available subject to MOQ.
MOQ is 1,000 units for standard catalogue models. Lead time for standard orders is confirmed at order; OEM or custom-firmware orders are project-based and agreed at the specification stage.
We ship worldwide from Jiaxing via sea, air or express, supporting EXW, FOB Ningbo, CIF and DDP. Full export documentation — commercial invoice, packing list, certificate of origin and production test reports — is provided with every shipment.