Thermostatic valve & pressure valve

Thermostatic valve & pressure valve Manufacturer & Supplier in China

As a factory-direct HVAC valve manufacturer and supplier in China, we produce CE certified thermostatic mixing valves, pressure relief valves, freeze and scald protection valves, and flow balancing valves at our own facility in Jiaxing, Zhejiang Province. With in-house CNC machining, dedicated assembly lines, and 100% pressure and function testing on every unit, we supply OEM valve system integrators and HVAC distributors in 90+ countries with consistent, independently verified flow control components for hydronic heating, solar thermal, healthcare and industrial applications.

When you source HVAC valves from Legom, you specify components engineered to meet EN 1111, NHS D08, ASSE1070, ASSE1016, ASSE1017, CSA B125.3, NSF 61/372 and other international standards — backed by CE certification and, for selected TMV models, independent third-party laboratory verification.

Quality Meets Reliability
WRAS ACS CE
WRAS, ACS & CE Certified

Certified HVAC valves for international standards.

Precise Mixing & Flow Control

Accurate thermostatic mixing and balancing control.

Built-in Scald & Freeze Protection

Protects pipework and end users from temperature failure.

Corrosion-Resistant Brass

Durable brass construction for long service life.

< 1 2 3 >

01 Product Range

We manufacture 68 HVAC valve models across six functional categories — thermostatic mixing valves, temperature and pressure relief valves, freeze and scald protection valves, flow balancing valves, fan coil components, and the HFT thermostatic series. All models are CE certified and manufactured at our own facility in Jiaxing, Zhejiang. OEM and ODM customization is available across the full range.

Thermostatic Mixing Valves (TMV)

Blend hot and cold water to deliver a stable outlet temperature, protecting users from scalding and ensuring consistent delivery temperature in residential, commercial and healthcare applications.

ModelTypeKey SpecificationStandardsTypical Application
910010CCStandard TMVBrass body, adjustable set pointCEDomestic hot water, residential mixing
910018CCSolar TMVDesigned for solar water heater outletsEN 1111, CESolar thermal hot water systems
910064CCElectronic TMVElectronically controlled set pointCESmart building hot water management
910054NTCirculation TMVMulti-point thermostatic circulation controlCEHot water circulation systems
910021NTHigh-Flow Central TMV60L/min; 4×G3/4″; 16 bar static; 30-65°CCECentral hot water mixing for multi-point distribution
910034NTMini TMVIntegral check valves and strainers; auto shutoffASSE1070, CSA B125.3, NSF 61/372, CEPoint-of-use safety; healthcare; aged care
910024CCSolar Connection KitThermostatic connection kit for solar collectorsCESolar thermal system connections

Temperature and Pressure Relief Valves (TP Valve)

Safety devices installed on boilers, water heaters and pressurised storage systems. They open automatically when pressure or temperature exceeds the rated threshold.

ModelKey SpecificationTypical Application
930004NTAutomatic reset; wax inspection system; DN size optionsBoilers, water heaters, pressurised storage vessels
930008NTHigh-capacity TP relief; larger body formatCommercial boilers, large-capacity hot water storage

Freeze and Scald Protection Valves

Guard pipework and end users from the two most common temperature-related failure modes in hydronic systems: pipe freezing and scalding at hot water outlets.

ModelTypeKey Temperature DataTypical Application
910026NTFreeze ProtectionInitial open: 1.6°C; Full open: 4°C; Full close: 7°COutdoor pipework, heat pump systems, cold climates
910028NTMinimum Temperature GuardInitial open: 36.7°C; Full open: 43.3°C; Closes below 35°CSolar and storage hot water outlets; Legionella control

Flow Control and Balancing Valves

Ensure equal flow distribution across all circuits in a hydronic system, preventing dominant circuits from starving other zones.

ModelTypeKey SpecificationTypical Application
930001NTDynamic Balancing ValveAutomatic flow limiting; prevents excessive flow rateHydronic heating circuits, HVAC distribution
930005NTDynamic Flow BalancingDifferential pressure independent flow controlMulti-zone HVAC, chilled water systems
910033NTWater Return ControlControls hot water return circuit temperatureDomestic hot water recirculation systems

Fan Coil Components

Regulate the flow of water or glycol solution into fan coil units, enabling precise zone temperature control in buildings without ductwork.

ModelKey SpecificationTypical Application
930019NTKVS 2.7 m³/h; -10°C to 120°C; 25 bar; max 50% glycolFan coil units, HVAC zoning in hotels, offices, apartments

02 How to Select the Right HVAC Valve

With 68 models across 6 functional categories, selecting the correct HVAC valve requires matching three parameters from your system design to the correct product group:

1
Function Required

Thermostatic mixing, pressure/temperature relief, freeze or scald protection, flow balancing, or fan coil flow regulation. Each function requires a different product category.

2
Pressure & Temperature Limits

Confirm the maximum working pressure (bar) and operating temperature range. This determines which valve model, body material and safety relief threshold is appropriate.

3
Connection Size & Thread

Available in G1/2, G3/4 and G1 (BSP) thread sizes and selected NPT configurations. Confirm pipe diameter and thread standard before specifying a model.

03 Manufacturing Capacity

Production LocationJiaxing, Zhejiang Province, China
MOQ1,000 units
Lead Time — Standard ModelsConfirmed at order; contact the team for current scheduling
Lead Time — Custom / ODMProject-based; agreed with the engineering team at specification stage
Primary Export MarketsEurope (primary); 90+ countries served globally
ShippingSea freight / Air freight / Express courier
Quality Inspection100% pressure and function testing before dispatch; batch test certificates available
CertificationsCE, RoHS
OEM Partners400+ globally

04 Production Process

  1. Raw Material Inspection — Brass and SS stock verified for composition and dimensional tolerance before machining.
  2. Component Sorting — Springs, collars and valve components sorted and staged for assembly under controlled conditions.
  3. Assembly Line — Valve bodies, seats and internals assembled on dedicated production lines with operator quality checks.
  4. Pneumatic Press — Cap and seal crimping under pneumatic press, ensuring consistent sealing force across every unit.
  5. Endurance Testing — Automated cycling and pressure endurance test rigs verify valve performance across rated operating cycles.
  6. Certification Check — Final compliance verification for CE and applicable international standards before dispatch.

05 OEM Service Covers

Specification review — valve function, pressure, temperature and connection size
Custom temperature calibration — wax element activation and set point adjustment
Dimensional & thread customization — body dimensions, port configuration, BSP/NPT
Sample & approval cycle — third-party test reports available for regulatory submission
Production batch certification — pressure and functional performance certificates
Private label / white label — custom packaging and labelling under strict confidentiality

06 Applications

Underfloor heating & hydronic systems — mixing valves regulate floor water temperature (typically 35-55°C); balancing valves ensure equal flow. 910010CC, 910021NT and 930001NT are commonly specified.
Solar thermal systems — 910018CC Solar TMV and 910024CC Solar Connection Kit blend high-temperature collector output to a consistent, safe supply; 910028NT ensures minimum delivery temperature for Legionella control.
Healthcare & commercial buildings — TMVs are mandatory under NHS D08, ASSE 1016/1070. 910034NT Mini TMV (ASSE1070, CSA B125.3, NSF 61/372) is purpose-built for healthcare point-of-use.
Residential hot water safety — 910026NT freeze protection valve opens at 1.6°C to drain at-risk pipe; 910028NT minimum temperature guard prevents lukewarm delivery that could harbour Legionella.
Heat pump & boiler systems — 930004NT and 930008NT TP relief valves protect heat exchangers and storage vessels from over-pressurisation; 910033NT maintains efficient hot water circulation.
Industrial & process applications — 910021NT high-flow mixing valve handles up to 60L/min at 16 bar; 930005NT dynamic balancing maintains stable differential pressure across variable-flow circuits.

07 FAQ

What types of HVAC valves does Legom manufacture?

68 models across six categories: thermostatic mixing valves (TMV), temperature and pressure relief valves (TP valves), freeze and scald protection valves, dynamic flow balancing and pressure limiting valves, fan coil component valves, and the HFT thermostatic series for faucet and shower valve integration.

What is a thermostatic mixing valve and how does it work?

It blends hot and cold water to deliver a consistent outlet temperature. At its core is a wax thermostatic element that expands as outlet temperature rises and contracts as it falls, mechanically adjusting the hot-to-cold ratio to maintain the set point without electrical input.

What is the difference between the freeze protection and scald protection valves?

910026NT opens at 1.6°C to drain pipe and prevent ice damage, closing again at 7°C — it protects the pipe. 910028NT is a minimum temperature guard that stays closed below 35°C and opens above 36.7°C, ensuring only adequately hot water is delivered — important for Legionella control. Both are passively operated by wax elements.

What certifications do Legom HVAC valves hold?

CE certified across the full range. Selected models carry additional certifications: 910034NT Mini TMV holds ASSE1070, CSA B125.3 and NSF 61/372; 910018CC Solar TMV is certified to EN 1111.

What materials are Legom HVAC valves made from?

Primarily brass — the industry standard for thermostatic mixing and flow control due to corrosion resistance and durability. Selected HFT models are available with electroplated or natural pickled finishes. Stainless steel options are available for marine or aggressive environments.

What connection sizes are available?

G1/2, G3/4 and G1 BSP thread configurations. 910021NT central mixing valve uses 4×G3/4″ ports. Other standards including NPT and larger bores are available on request.

Are you a manufacturer or a trading company?

We are a manufacturer. All HVAC valves are produced at our own facility in Jiaxing using in-house CNC machining, assembly and pressure-testing equipment. Factory visits are welcome by appointment.

What is the MOQ and lead time for HVAC valve orders?

MOQ is 1,000 units for both standard and custom models. Standard lead time is confirmed at order; custom or ODM orders are project-based and agreed at the specification stage.

What are the shipping and delivery options?

Worldwide shipping from Jiaxing via sea, air or express, supporting EXW, FOB Ningbo, CIF and DDP, with full export documentation — commercial invoice, packing list, certificate of origin and production test reports.

Can Legom supply HVAC valves with OEM branding?

Yes. Valves can be supplied under your brand with custom packaging, labelling and product documentation. All OEM and private label projects are handled under strict confidentiality agreements.

Wechat-SMLG WhatsApp-SMLG
Product menu buttons for small screen devices
Categories
Product menu buttons for small screen devices
Contact